{"id":10073,"date":"2020-08-07T17:45:45","date_gmt":"2020-08-07T17:45:45","guid":{"rendered":"https:\/\/cyflexdoc.wpengine.com\/?page_id=10073"},"modified":"2021-01-13T19:25:02","modified_gmt":"2021-01-13T19:25:02","slug":"runtqui","status":"publish","type":"page","link":"https:\/\/cyflex.com\/index.php\/usage-help-manual\/5-data-display\/runtqui\/","title":{"rendered":"runqtui"},"content":{"rendered":"<h3>Purpose:<\/h3>\n<dl>\n<dd><\/dd>\n<\/dl>\n<p style=\"padding-left: 40px;\">Configure and start the Operator Display.<\/p>\n<h3>Enter:<\/h3>\n<p style=\"padding-left: 40px;\"><strong>runqtui <\/strong>[configuration options] spec_file.ui &amp;<\/p>\n<h3>Where:<\/h3>\n<dl>\n<dd>\n<div>\n<table style=\"width: 89.54%;\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col \/>\n<col \/><\/colgroup>\n<tbody>\n<tr>\n<td style=\"width: 81.74px;\">spec_file.ui<\/td>\n<td style=\"width: 970.62px;\">Specify a configuration file. The file must end with the &#8220;.ui&#8221; extension.\u00a0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/dd>\n<\/dl>\n<dl>\n<dd>\n<div>\n<p><strong>runqtui<\/strong> configuration options are:<\/p>\n<p><span style=\"text-decoration: underline;\">CyFlex Variables Locking Options<\/span><\/p>\n<table style=\"width: 87.84%; height: 120px;\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col \/>\n<col \/><\/colgroup>\n<tbody>\n<tr style=\"height: 24px;\">\n<td style=\"width: 23.14%; height: 24px;\">-lnone<\/td>\n<td style=\"width: 114.5%; height: 24px;\">Specify this option to exclude use of the LockedVariable property. This is the default.\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 23.14%; height: 48px;\">-ladmin<\/td>\n<td style=\"width: 114.5%; height: 48px;\">Specify this option to use Administrative mode. Locking is performed based on the widget&#8217;s property.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 23.14%; height: 24px;\">-lall<\/td>\n<td style=\"width: 114.5%; height: 24px;\">Specify this option to ignore the LockedVariable property value and lock all widgets.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 23.14%; height: 24px;\">-lprop<\/td>\n<td style=\"width: 114.5%; height: 24px;\">Specify this option to use the \u00a0LockedVariable property to determine whether a widget is locked.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/dd>\n<\/dl>\n<p style=\"padding-left: 20px;\"><span style=\"text-decoration: underline;\">Configuration Save Options<\/span><\/p>\n<dl>\n<dd>\n<div>\n<table style=\"width: 89.01%;\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col \/>\n<col \/><\/colgroup>\n<tbody>\n<tr>\n<td style=\"width: 22.4%;\">-ssave<\/td>\n<td style=\"width: 137.99%;\">Specify this option to enable &#8220;save&#8221; or &#8220;save as&#8221; of the .ui file.\u00a0This is the default.<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 22.4%;\">-ssaveas<\/td>\n<td style=\"width: 137.99%;\">Specify this option to only enable &#8220;save as&#8221; of the .ui file to a different filename.<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 22.4%;\">-snone<\/td>\n<td style=\"width: 137.99%;\">Specify this option to disallow changes to the user interface.<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 22.4%;\">-nomenubar<\/td>\n<td style=\"width: 137.99%;\">Specify this option to hide the menu bar and tool bar on the user interface.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/dd>\n<\/dl>\n<h3>Example:<\/h3>\n<p style=\"padding-left: 0px;\">runqtui\u00a0\u00a0 op_dsply.ui &amp;<\/p>\n<p>The above example will start the Operator Display program and display the contents from the \/specs\/op_dsply.ui file.<\/p>\n<p>runqtui -lall -lnomenubar\u00a0 op_dsply.ui &amp;<\/p>\n<p>The above example will start the Operator Display program and display the contents from the \/specs\/op_dsply.ui file.\u00a0 All widgets on the Operator will be locked from changes getting made.\u00a0 Also, the menu bar and tool bar will not be shown within the Operator Display.<\/p>\n<dl>\n<dd><\/dd>\n<\/dl>\n<h3>Notes:<\/h3>\n<h3>See Also:<\/h3>\n<p style=\"padding-left: 40px;\"><a href=\"\/wp-content\/uploads\/Operator-Display-Program.pdf\">Operator Display User Guide<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Purpose: Configure and start the Operator Display. Enter: runqtui [configuration options] spec_file.ui &amp; Where: spec_file.ui Specify a configuration file. The file must end with the &#8220;.ui&#8221; extension.\u00a0 runqtui configuration options are: CyFlex Variables Locking Options -lnone Specify this option to exclude use of the LockedVariable property. This is the default.\u00a0 -ladmin Specify this option to [&hellip;]<\/p>\n","protected":false},"author":35,"featured_media":0,"parent":10052,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-10073","page","type-page","status-publish","hentry"],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/pages\/10073","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/users\/35"}],"replies":[{"embeddable":true,"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/comments?post=10073"}],"version-history":[{"count":0,"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/pages\/10073\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/pages\/10052"}],"wp:attachment":[{"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/media?parent=10073"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}