{"id":3317,"date":"2019-02-12T16:09:01","date_gmt":"2019-02-12T16:09:01","guid":{"rendered":"https:\/\/cyflexdoc.wpengine.com\/usage-help-manual\/8-smart-instrument-interfaces\/aktestintftir\/"},"modified":"2025-07-24T10:47:57","modified_gmt":"2025-07-24T15:47:57","slug":"aktestintftir","status":"publish","type":"page","link":"https:\/\/cyflex.com\/index.php\/usage-help-manual\/16-smart-instrument-interfaces\/aktestintftir\/","title":{"rendered":"AkTestIntFTIR"},"content":{"rendered":"<div>\n<h3>Purpose:<\/h3>\n<\/div>\n<dl>\n<dd>\n<p>Use the test interface functions for instruments that use the FTIR interface protocol, processing commands, responses, and timers in a continuous loop.<\/p>\n<\/dd>\n<\/dl>\n<h3>Enter:<\/h3>\n<dl>\n<dd>\n<p><strong>AkTestIntFTIR<\/strong> &lt;spec_file&gt; [p=priority] [i=interval] [v=verbose_file] [+c] [+q] [a0=&lt;asset_lab&gt;] &lt;intervall&gt;<\/p>\n<\/dd>\n<\/dl>\n<h3>Where:<\/h3>\n<dl>\n<dd>\n<div>\n<table style=\"width: 83.5342%; height: 192px;\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col \/>\n<col \/> <\/colgroup>\n<tbody>\n<tr style=\"height: 56px;\">\n<td style=\"width: 15.7424%; height: 56px;\">\n<p>spec_file<\/p>\n<\/td>\n<td style=\"width: 84.0787%; height: 56px;\">\n<p>Specify the path for resource manager specifications.<\/p>\n<\/td>\n<\/tr>\n<tr style=\"height: 56px;\">\n<td style=\"width: 15.7424%; height: 56px;\">\n<p>p=priority<\/p>\n<\/td>\n<td style=\"width: 84.0787%; height: 56px;\">\n<p>Optional. Specify the system priority level to assign to the process. The default is 15.<\/p>\n<\/td>\n<\/tr>\n<tr style=\"height: 80px;\">\n<td style=\"width: 15.7424%; height: 80px;\">\n<p>i=interval<\/p>\n<\/td>\n<td style=\"width: 84.0787%; height: 80px;\">\n<p>Optional. Specify the time interval, in milliseconds, to indicate how often the master scheduler will be informed that this process is still running. The default is 1000 ms.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 15.7424%;\">\n<p>[v=verbose_file<\/p>\n<\/td>\n<td style=\"width: 84.0787%;\">\n<p>Optional. Specify the file for verbose output.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 15.7424%;\">\n<p>+c<\/p>\n<\/td>\n<td style=\"width: 84.0787%;\">\n<p>Optional. Specify this flag to indicate watchdog criticality.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 15.7424%;\">\n<p>+q<\/p>\n<\/td>\n<td style=\"width: 84.0787%;\">\n<p>Optional. Specify this flag to indicate quiet mode; don&#8217;t repeat requests.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 15.7424%;\">\n<p>a0=&lt;asset_lab&gt;<\/p>\n<\/td>\n<td style=\"width: 84.0787%;\">\n<p>Optional. Specify a valid asset real variable label.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 15.7424%;\">\n<p>intervall<\/p>\n<\/td>\n<td style=\"width: 84.0787%;\">\n<p>Specify a timer name for the master scheduler.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/dd>\n<\/dl>\n<h3>Example:<\/h3>\n<dl>\n<dd>\n<p><strong>AkTestIntFTIR <\/strong>mySpecFile 12 1000\u00a0<\/p>\n<p>The preceding processes mySpecFile at a system priority level of 12 and signals the master scheduler once every second.<\/p>\n<\/dd>\n<\/dl>\n<h3>Notes:<\/h3>\n<dl>\n<dd>\n<p>&nbsp;<\/p>\n<\/dd>\n<\/dl>\n<h3>See Also:<\/h3>\n<dl>\n<dd>\n<p><a href=\"https:\/\/cyflex.com\/wp-content\/uploads\/Master-Scheduler-Task.pdf\">Master Scheduler<\/a><\/p>\n<\/dd>\n<\/dl>\n","protected":false},"excerpt":{"rendered":"<p>Purpose: Use the test interface functions for instruments that use the FTIR interface protocol, processing commands, responses, and timers in a continuous loop. Enter: AkTestIntFTIR &lt;spec_file&gt; [p=priority] [i=interval] [v=verbose_file] [+c] [+q] [a0=&lt;asset_lab&gt;] &lt;intervall&gt; Where: spec_file Specify the path for resource manager specifications. p=priority Optional. Specify the system priority level to assign to the process. The [&hellip;]<\/p>\n","protected":false},"author":47,"featured_media":0,"parent":1955,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-3317","page","type-page","status-publish","hentry"],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/pages\/3317","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/users\/47"}],"replies":[{"embeddable":true,"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/comments?post=3317"}],"version-history":[{"count":0,"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/pages\/3317\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/pages\/1955"}],"wp:attachment":[{"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/media?parent=3317"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}