{"id":3403,"date":"2019-02-12T16:09:09","date_gmt":"2019-02-12T16:09:09","guid":{"rendered":"https:\/\/cyflexdoc.wpengine.com\/usage-help-manual\/9-ecm-communication\/asam3_specs\/"},"modified":"2025-07-29T11:14:56","modified_gmt":"2025-07-29T16:14:56","slug":"asam3_specs","status":"publish","type":"page","link":"https:\/\/cyflex.com\/index.php\/usage-help-manual\/17-ecm-communication\/asam3_specs\/","title":{"rendered":"asam3_specs"},"content":{"rendered":"<h3>Purpose:<\/h3>\n<dl>\n<dd>Process ASAM3 TCP Monitoring Specifications to configure the asam3cli task by reading and verifying specification files.<\/dd>\n<\/dl>\n<h3>Enter:<\/h3>\n<dl>\n<dd><strong>asam3_specs<\/strong> [spec_file] [-v] [-reset] [rebuild] [INCA|CANApe]<\/dd>\n<\/dl>\n<h3>Where:<\/h3>\n<dl>\n<dd>\n<div>\n<table style=\"width: 100%; height: 240px;\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col \/>\n<col \/> <\/colgroup>\n<tbody>\n<tr style=\"height: 48px;\">\n<td style=\"height: 48px;\">spec_file<\/td>\n<td style=\"height: 48px;\">Optional. Specify the specification filename that contains the ECM variable names to read and the CyFlex variable names where the values will be placed. The default file is asam3_specs.nnn.<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"height: 48px;\">-v<\/td>\n<td style=\"height: 48px;\">Optional. Specify this flag to read the specification file and verify the validity of the CyFlex variable name values. Detected errors will be displayed on the screen.\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 72px;\">\n<td style=\"height: 72px;\">-reset<\/td>\n<td style=\"height: 72px;\">Optional. Specify this option to rewrite the\u00a0specification file with unique CyFlex variable names and exit for rerun<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"height: 48px;\">-rebuild<\/td>\n<td style=\"height: 48px;\">Optional. Specify this option to only regenerate CyFlex variable names only for invalid or missing ones<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px;\">INCA|CANape<\/td>\n<td style=\"height: 24px;\">\n<p>Optional. Specify either INCA or CANape:<\/p>\n<ul>\n<li>Specify INCA to indicate asam3_specs is communicating with the INCA system.\u00a0<\/li>\n<li>Specify CANape to indicate asam3_specs is communicating with the CANape system.<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/dd>\n<\/dl>\n<h3>Example:<\/h3>\n<dl>\n<dd><strong>asam3_specs<\/strong><br \/>\nThe above command processes asam3_specs.nnn file\u00a0for ASAM3 monitoring specifications, where nnn is the local test cell number.<\/p>\n<p><strong>asam3_specs\u00a0<\/strong> -v<br \/>\nThis command processes the asam3_specs.nnn file like the above example. The asam3_specs.nnn file will then be read and the CyFlex variable names will be verified to be valid or not valid.<\/p>\n<p><b>asam3_specs<\/b>\u00a0 spec_file\u00a0 -v<br \/>\nThis command processes a specified spec_file to be processed like the above examples. The spec_file will be read and the CyFlex variable names will be verified to be valid or not valid.<\/p>\n<p><b>asam3_specs<\/b>\u00a0 spec_file\u00a0 INCA<br \/>\nThis command processes the INCA spec_file like the above examples. INCA will work with the -v option if it is also specified.<\/p>\n<p><b>asam3_specs<\/b>\u00a0 spec_file\u00a0 CANape<br \/>\nThis command processes the CANape spec_file like the above examples. CANape will work with the -v option if it is also specified.<\/p>\n<p><b>asam3_specs<\/b> spec_file -rebuild<br \/>\nThis command revises the ECM0 Section of the spec file as follows:<\/p>\n<p>Before:<\/p>\n<pre><span style=\"font-size: 12pt;\">ECM0\u00a0 1000   DYNAMICDAQ<\/span>\r\n<span style=\"font-size: 12pt;\">AcltrPosCrd.ppAcltrPdlPos.deVal\u00a0 \u00a0%\u00a0 \u00a0AcltrPosCrd_ppAcltrPdlPos_deval<\/span>\r\n<span style=\"font-size: 12pt;\">AftInIntfProc.ppAftSysExhPr.deVal kPa -<\/span><\/pre>\n<p>After:<\/p>\n<pre><span style=\"font-size: 12pt;\">ECM0\u00a0 1000   DYNAMICDAQ<\/span>\r\n<span style=\"font-size: 12pt;\">AcltrPosCrd.ppAcltrPdlPos.deVal  \u00a0 %\u00a0  AcltrPosCrd_ppAcltrPdlPos_deval<\/span>\r\n<span style=\"font-size: 12pt;\">AftInpIntfProc.ppAftSysExhPr.deVal kPa AftInpIntfProc_csar_0<\/span><\/pre>\n<p><b>asam3_specs<\/b> spec_file -reset<br \/>\nThis command revises the ECM0 Section of the spec file as follows:<\/p>\n<p>Before:<\/p>\n<pre><span style=\"font-size: 12pt;\">ECM0  1000   DYNAMICDAQ<\/span>\r\n<span style=\"font-size: 12pt;\">AccltrPdlPosnCrd.ppAccltrPdlPosn.deVal\u00a0 \u00a0%\u00a0\u00a0 AccltrPdlPosnCrd_ppcAccltrPdlPosn_deval<\/span>\r\n<span style=\"font-size: 12pt;\">AftInpIntfProc.ppAftSysExhPr.deVal\u00a0 \u00a0 \u00a0 \u00a0kPa\u00a0-<\/span><\/pre>\n<p>After:<\/p>\n<pre><span style=\"font-size: 12pt;\">ECM0  1000   DYNAMICDAQ<\/span>\r\n<span style=\"font-size: 12pt;\">AccltrPdlPosnCrd.ppAccltrPdlPosn.deVal\u00a0 \u00a0%\u00a0\u00a0\u00a0AccltrPdlPosnCrd_csar_0<\/span>\r\n<span style=\"font-size: 12pt;\">AftInpIntfProc.ppAftSysExhPr.deVal\u00a0 \u00a0 \u00a0 \u00a0kPa AftInpIntfProc_csar_1<\/span><\/pre>\n<p><b>asam3_specs<\/b> spec_file -reset<br \/>\nThis command revises the ECM0 Section of the spec file where only ECM variable names are provided as follows:<\/p>\n<p>Before:<\/p>\n<pre><span style=\"font-size: 12pt;\">ECM0\u00a0 1000   DYNAMICDAQ<\/span>\r\n<span style=\"font-size: 12pt;\">AccltrPdlPosnCoord.ppAccltrPdlPosn.deVal<\/span>\r\n<span style=\"font-size: 12pt;\">AftInpIntfProc.ppAftSysExhPr.deVal<\/span><\/pre>\n<p>After:<\/p>\n<pre><span style=\"font-size: 12pt;\">ECM0  1000   DYNAMICDAQ<\/span>\r\n<span style=\"font-size: 12pt;\">AccltrPdlPosnCoord.ppAccltrPdlPosn.deVal\u00a0 None\u00a0 AccltrPdlPosnCoord_csar_0<\/span>\r\n<span style=\"font-size: 12pt;\">AftInpIntfProc.ppAftSysExhPr.deVal\u00a0 \u00a0 \u00a0 \u00a0 None \u00a0AftInpIntfProc_csar_1<\/span><\/pre>\n<\/dd>\n<\/dl>\n<h3>Notes:<\/h3>\n<dl>\n<dd>The program may display warnings about duplicates when using -reset or -rebuild options. After -reset, rerun the command as it exits after processing.<\/dd>\n<\/dl>\n<h3>See Also:<\/h3>\n<dl>\n<dd><a href=\"https:\/\/cyflex.com\/index.php\/usage-help-manual\/17-ecm-communication\/asam3_initvar\/\">asam3_initvar<\/a>,\u00a0<a href=\"https:\/\/cyflex.com\/index.php\/usage-help-manual\/17-ecm-communication\/asam3cli\/\">asam3cli<\/a>, <a href=\"\/wp-content\/uploads\/ASAM3-Interface-Setup.pdf\">ASAM3 Interface Setup<\/a><\/dd>\n<\/dl>\n","protected":false},"excerpt":{"rendered":"<p>Purpose: Process ASAM3 TCP Monitoring Specifications to configure the asam3cli task by reading and verifying specification files. Enter: asam3_specs [spec_file] [-v] [-reset] [rebuild] [INCA|CANApe] Where: spec_file Optional. Specify the specification filename that contains the ECM variable names to read and the CyFlex variable names where the values will be placed. The default file is asam3_specs.nnn. [&hellip;]<\/p>\n","protected":false},"author":47,"featured_media":0,"parent":1956,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-3403","page","type-page","status-publish","hentry"],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/pages\/3403","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/users\/47"}],"replies":[{"embeddable":true,"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/comments?post=3403"}],"version-history":[{"count":0,"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/pages\/3403\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/pages\/1956"}],"wp:attachment":[{"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/media?parent=3403"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}