{"id":3900,"date":"2019-02-12T16:10:07","date_gmt":"2019-02-12T16:10:07","guid":{"rendered":"https:\/\/cyflexdoc.wpengine.com\/usage-help-manual\/8-smart-instrument-interfaces\/serfrdly\/"},"modified":"2020-10-01T18:15:50","modified_gmt":"2020-10-01T18:15:50","slug":"serfrdly","status":"publish","type":"page","link":"https:\/\/cyflex.com\/index.php\/usage-help-manual\/16-smart-instrument-interfaces\/serfrdly\/","title":{"rendered":"serFrdly"},"content":{"rendered":"<div>\n<h3>Purpose:<\/h3>\n<\/div>\n<dl>\n<dd>\n<p>Spawn a serial port interface between a test cell and a Queue Manager.<\/p>\n<\/dd>\n<\/dl>\n<h3>Enter:<\/h3>\n<dl>\n<dd>\n<p><strong>serFrdly<\/strong> &lt;client = name&gt; [file=specFileName] [asc_root=name]<\/p>\n<\/dd>\n<\/dl>\n<h3>Where:<\/h3>\n<dl>\n<dd>\n<div>\n<table style=\"width: 100%;\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col \/>\n<col \/> <\/colgroup>\n<tbody>\n<tr>\n<td style=\"width: 9.56%;\">\n<p>client=name<\/p>\n<\/td>\n<td style=\"width: 90.27%;\">\n<p>Required. Specify the name of the client to place in the queue for access to an emission bench. The &#8216;name&#8217; must be one of the entries in the \/specs\/iQueue_specs file.\u00a0<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 9.56%;\">\n<p>file=filename<\/p>\n<\/td>\n<td style=\"width: 90.27%;\">\n<p>Optional. Specify the iQueue spec filename that is read by all iQueue processes. The default is \/specs\/iQueue_specs.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 9.56%;\">\n<p>asc_root=name<\/p>\n<\/td>\n<td style=\"width: 90.27%;\">\n<p>Optional. Specify the root name of the spec file\u00a0 used by ASC. It is also the root name of the events that are created to allow communication between the &#8216;client&#8217; and this process. The default is IQUE.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/dd>\n<\/dl>\n<h3>Example:<\/h3>\n<dl>\n<dd>\n<p><strong>serFrdly<\/strong> client=tc1 &amp;<br \/>\nThe above spawns the serial port interface and places it in the background. The serial port is connected to a device that has been assigned the name &#8216;tc1&#8217;. The default spec file &#8216;\/specs\/iQueue_specs\u2019 and ASC root device name of \u2019IQUE&#8217; will be used<\/p>\n<p><strong>serFrdly<\/strong> client=tc2 file=\/specs\/bench_specs asc_root=BNCH<br \/>\nThe above spawns the serial port interface and places it in the background. The serial port is connected to a device that has been assigned the name &#8216;tc2&#8217;. The spec file &#8216;\/specs\/bench_specs\u2019 and ASC root device name of \u2018BNCH&#8217; will be used.<\/p>\n<\/dd>\n<\/dl>\n<h3>Notes:<\/h3>\n<dl>\n<dd>\n<p>&nbsp;<\/p>\n<\/dd>\n<\/dl>\n<h3>See Also:<\/h3>\n<dl>\n<dd>\n<p><a href=\"\/wp-content\/uploads\/Fridley-Test-Cell-Interface-with-Horiba.pdf\">Fridley Test Cell Interface with Horiba\u00a0<\/a><\/p>\n<\/dd>\n<\/dl>\n","protected":false},"excerpt":{"rendered":"<p>Purpose: Spawn a serial port interface between a test cell and a Queue Manager. Enter: serFrdly &lt;client = name&gt; [file=specFileName] [asc_root=name] Where: client=name Required. Specify the name of the client to place in the queue for access to an emission bench. The &#8216;name&#8217; must be one of the entries in the \/specs\/iQueue_specs file.\u00a0 file=filename Optional. [&hellip;]<\/p>\n","protected":false},"author":47,"featured_media":0,"parent":1955,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-3900","page","type-page","status-publish","hentry"],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/pages\/3900","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/users\/47"}],"replies":[{"embeddable":true,"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/comments?post=3900"}],"version-history":[{"count":0,"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/pages\/3900\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/pages\/1955"}],"wp:attachment":[{"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/media?parent=3900"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}