{"id":4033,"date":"2019-02-12T16:10:22","date_gmt":"2019-02-12T16:10:22","guid":{"rendered":"https:\/\/cyflexdoc.wpengine.com\/usage-help-manual\/21-default-specification-files\/tri_logr_spec-12\/"},"modified":"2026-08-06T15:45:38","modified_gmt":"2026-08-06T20:45:38","slug":"tri_logr_spec-12","status":"publish","type":"page","link":"https:\/\/cyflex.com\/index.php\/usage-help-manual\/27-default-specification-files\/tri_logr_spec-12\/","title":{"rendered":"tri_logr_spec.12"},"content":{"rendered":"<div>\n<h3>Purpose:<\/h3>\n<\/div>\n<dl>\n<dd>\n<p>Generates a CyFlex logr_spec file. The spec file will contain all the data from the logr_spec_in file + if any ECM_DATA_SOURCES are specified within the tri_specs.dat file,<br \/>\nthe @CSAR_LABEL keyword will be added with the appropriate keyword + all tri_specs.dat DATA_CHANNELS in the scan list + list of pnp logical variables if pnp subsystems are specified + list of variables for each specified subsystem from the subsystems file<\/p>\n<\/dd>\n<\/dl>\n<h3>Enter:<\/h3>\n<dl>\n<dd>\n<p><strong>tri_logr_spec.12<\/strong> &lt;logr_spec_out=logr_specO&gt; &lt;logr_spec_in=logr_specI&gt; &lt;tri_specs=tri_specs_file&gt;<\/p>\n<\/dd>\n<\/dl>\n<h3>Where:<\/h3>\n<dl>\n<dd>\n<div>\n<table style=\"width: 93.25%;\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col \/>\n<col \/> <\/colgroup>\n<tbody>\n<tr>\n<td style=\"width: 11.4%;\">\n<p>logr_spec_out<\/p>\n<\/td>\n<td style=\"width: 273.97%;\">\n<p>Specify the pathname of the logr spec output file.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 11.4%;\">\n<p>logr_spec_in<\/p>\n<\/td>\n<td style=\"width: 273.97%;\">\n<p>Specify the pathname of the logr spec input file.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 11.4%;\">\n<p>tri_specs<\/p>\n<\/td>\n<td style=\"width: 273.97%;\">\n<p>Specify the pathname of the tri specs file.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/dd>\n<\/dl>\n<h3>Example:<\/h3>\n<dl>\n<dd>\n<div><strong>tri_logr_spec.12<\/strong> logr_spec_out=\/esvd_data\/CTH_EUL\/logr_spec_12.dat \u00a0<br \/>\n\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0logr_spec_in=\/esvd_data\/specs\/logr_spec.base\u00a0<br \/>\n\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0tri_specs=\/esvd_data\/CTH_EUL\/tri_specs.dat \u00a0<\/div>\n<\/dd>\n<\/dl>\n<h3>Notes:\u00a0<\/h3>\n<dl>\n<dd>\u00a0 \u00a0 \u00a0\u00a0 &#8211; \/e\/&lt;t&gt;\/\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0&#8216;logr_spec_12.dat&#8217;\u00a0\u00a0<br \/>\n\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0&#8211; \/e\/&lt;s&gt;\/\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0&#8216;logr_spec.base&#8217;<br \/>\n\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0&#8211; \/e\/&lt;t&gt;\/\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0&#8216;tri_specs.dat&#8217;\u00a0\u00a0<br \/>\n\u00a0<br \/>\n\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0where: \u00a0<\/p>\n<table style=\"width: 100%; border-collapse: collapse;\">\n<tbody>\n<tr>\n<td style=\"width: 11.1749%;\">e<\/td>\n<td style=\"width: 88.8151%;\">esvd_data<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 11.1749%;\">t<\/td>\n<td style=\"width: 88.8151%;\">test plan id of test<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 11.1749%;\">s<\/td>\n<td style=\"width: 88.8151%;\">specifications that apply<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 11.1749%;\">&#8216; &#8216;<\/td>\n<td style=\"width: 88.8151%;\">Contains specifications that apply to all tests ultimately replaced by the actual filename when the script &#8216;tri_file_name.12&#8217; is run.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\nEnsure all file paths are valid and accessible as the program will exit on file open errors.<\/dd>\n<\/dl>\n<h3>See Also:<\/h3>\n<dl>\n<dd>\n<p>&nbsp;<\/p>\n<\/dd>\n<\/dl>\n","protected":false},"excerpt":{"rendered":"<p>Purpose: Generates a CyFlex logr_spec file. The spec file will contain all the data from the logr_spec_in file + if any ECM_DATA_SOURCES are specified within the tri_specs.dat file, the @CSAR_LABEL keyword will be added with the appropriate keyword + all tri_specs.dat DATA_CHANNELS in the scan list + list of pnp logical variables if pnp subsystems [&hellip;]<\/p>\n","protected":false},"author":47,"featured_media":0,"parent":1968,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-4033","page","type-page","status-publish","hentry"],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/pages\/4033","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/users\/47"}],"replies":[{"embeddable":true,"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/comments?post=4033"}],"version-history":[{"count":3,"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/pages\/4033\/revisions"}],"predecessor-version":[{"id":15421,"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/pages\/4033\/revisions\/15421"}],"up":[{"embeddable":true,"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/pages\/1968"}],"wp:attachment":[{"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/media?parent=4033"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}