{"id":4160,"date":"2019-02-16T14:26:36","date_gmt":"2019-02-16T14:26:36","guid":{"rendered":"https:\/\/cyflexdoc.wpengine.com\/?page_id=4160"},"modified":"2025-09-03T11:55:51","modified_gmt":"2025-09-03T16:55:51","slug":"darts_datapoint","status":"publish","type":"page","link":"https:\/\/cyflex.com\/index.php\/usage-help-manual\/9-data-collection-data-logging\/darts_datapoint\/","title":{"rendered":"datapoint"},"content":{"rendered":"<h3>Purpose:<\/h3>\n<blockquote>\n<p>Control the sequencing and reporting of various channel measurements.<\/p>\n<p>Channels are specified in the \/specs\/pam_specs.nnn as Variable Lists, each delimited by a $ line. It handles time-averaged or instantaneous values, computes performance parameters, and writes to PAM Datapoint and local Fuel Log files.<\/p>\n<\/blockquote>\n<h3>Enter:<\/h3>\n<blockquote>\n<p><strong>datapoint <\/strong>[spc_specs.NNN_filename]\u00a0 [-csv] &amp;<\/p>\n<\/blockquote>\n<h3>Where:<\/h3>\n<table style=\"border-collapse: collapse; width: 93.6893%; height: 72px;\">\n<tbody>\n<tr style=\"height: 24px;\">\n<td style=\"width: 17.8398%; height: 24px;\">spc_specs.NNN_filename<\/td>\n<td style=\"width: 75.8665%; height: 24px;\">Optional. Specify the file for SPC specifications modified between fuel readings.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 17.8398%; height: 24px;\">-csv<\/td>\n<td style=\"width: 75.8665%; height: 24px;\">Optional. Specify this option to write the log file in .csv format.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Example:<\/h3>\n<p style=\"padding-left: 20px;\"><strong>datapoint<\/strong>\/cyflex\/datapoint\/datapoint2.spc -csv &amp;<\/p>\n<h3>Notes:<\/h3>\n<blockquote>\n<p>Variable values may be time-averaged or instantaneous. For averaged values, it configures channels and sends them to the stat_child task. Datapoint runs perpetually as part of CyFlex startup, responding to events. Specification =&gt; \/cyflex\/datapoint\/datapoint2.spc.<\/p>\n<p>After data for a Variable\u00a0List is available, various flow and performance computations are\u00a0made. The results are written into DARTS Datapoint and local Fuel\u00a0Log files.<\/p>\n<\/blockquote>\n<h3>See Also:<\/h3>\n<blockquote>\n<p><a href=\"https:\/\/cyflex.com\/wp-content\/uploads\/PAM-Data-Collection-and-Transfer.pdf\">PAM Data Collection and Transfer<\/a><\/p>\n<\/blockquote>\n","protected":false},"excerpt":{"rendered":"<p>Purpose: Control the sequencing and reporting of various channel measurements. Channels are specified in the \/specs\/pam_specs.nnn as Variable Lists, each delimited by a $ line. It handles time-averaged or instantaneous values, computes performance parameters, and writes to PAM Datapoint and local Fuel Log files. Enter: datapoint [spc_specs.NNN_filename]\u00a0 [-csv] &amp; Where: spc_specs.NNN_filename Optional. Specify the file [&hellip;]<\/p>\n","protected":false},"author":47,"featured_media":0,"parent":1960,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-4160","page","type-page","status-publish","hentry"],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/pages\/4160","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/users\/47"}],"replies":[{"embeddable":true,"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/comments?post=4160"}],"version-history":[{"count":0,"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/pages\/4160\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/pages\/1960"}],"wp:attachment":[{"href":"https:\/\/cyflex.com\/index.php\/wp-json\/wp\/v2\/media?parent=4160"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}