kw_report

Purpose:

Generate a facility wide utilization report for absorbing/motoring work

Requirements:

For data to be collected at the test cell, the integer variable “pwr_meas_type” must have a value of “1”. This should be set in the /cell/cell_special file after the $PI line

22 pwr_meas_type none 1 OFF

Enter:

kw_report interval=[day—week—fin_week—month—fin_month—year]
form=[1—2—3]
n=X
units=[units of energy]

Where:

interval

the time interval for the report options:
day
week (Sun-Sun)
fin_week (Mon-Mon) –DEFAULT
month (1st-end)
fin_month (Financial month – 4 or 5 wks)
year

form

the report format options:
1 => sorted by test cell number –DEFAULT
2 => sorted by power generated

n

the number of intervals to report – starting from the most recent and going backward

DEFAULT==1

units

the units of the “work” output – default [mw-h]

Example:

kw_report interval=fin_week form=2 > /data/util/KW_REPORT

Notes:

This program relies on the existence of several data files, including
/data/meters/power_report.NNN, when NNN is the test cell number of all the test cells at the site.

See Also:

meterlogall, metrlogall, gp_utl