Pre-requisites: You must be logged into a different account to change the username for the desired account. If you don’t already have a separate account to use, create one by running the following at the command prompt: sudo useradd -l <new_username> -d /home/<new_username> You must also disable Automatic Login of the account for which you
To change the login on a computer from tc1 (old) to tc3 (new), the following steps should be taken: sudo nedit /etc/kde/kdm/kdmrc Modify AutoLoginUser=tc3 (to be the cell number) Modify DefaultUser=tc3 To change on the computer: Click Start –> Administration –>Users and Groups – Enter the password when prompted Within the User Manager dialog:
Updating to Qt-4.8.7 which is binary compatible with Qt-4.7.4 will fix the issue. Applications don’t have to recompiled to use the new version. Don’t worry, if you need to roll back to the Qt-4.7.4 version, it is still on the system, and will only take couple changes to switch back. sudo yum install qt-everywhere-opensource-487 rpm
CyFlex Platform Overview Operating Systems: QNX 4.2 (message passing OS) Linux – Fedora 8, Scientific Linux 6 Programming Languages/Tools: C / C++ (shared code base for both OS) JAVA, Qt Hardware : Intel CPU ISA Bus – 11 slots typical PCI Bus – 6 slots typical Networking QNXnet, Ethernet TCP/IP – Customer’s Intranet & Internet
Overview of Supported I/O Hardware Opto SnapIO ethernet-based Gantner ethernet-based Metrabyte DAS16 family (DAS16G2, DAS1600) Transition Technology (MTL) National Instruments (various) Opto Optomux Scanivalve – Ethernet thermocouple module Ethercat Modbus Beckhoff AMD 9513 based counter/timers Interested in interfacing with a different piece of hardware? Enter a JIRA.
There are several possible causes that you can test with the utility “get_comp”. This utility lets you experimentally test and computed expression. If the expression has an error, it will return an “null” result. The “get_comp” utility is launch from the command line with 1 or 2 arguments. The 1st argument is the expression you
CyFlex provides several mechanisms for troubleshooting a gp_test abort. Used together, these mechanisms can help determine the cause of the abort. The mechanisms are: Display Screen Limit Report Error Log Trace Log Delta History EXAMPLE SCENARIO The 200-hour durability test being conducted at the cell goes down in the middle of the night. The technician