HP_set
Purpose:
-
Set a voltage setpoint for a Hewlett Packard programmable power supply.
Enter:
-
HP_set <action> [value] &
Where:
-
action
Specify any or all of the following actions:
- v to set voltage level
- vover to set voltage limit
- maxi to set current limit
- read_vstpt to read voltage setpoint
- read_vover to read voltage limit
- read_maxi to read current limit
- reset to reset PS to default
- enable to enable output
- disable to disable output
- read_enable to read the enable/disable state
value
Optional. Specify a value only with the ‘v’, ‘vover’, or ‘maxi’ action options.
Example:
-
HP_set v 12.6
Sets the voltage setpoint to 12.6 volts.HP_set v HP_voltage
Sets the voltage setpoint to the value contained in the ‘HP_voltage’ variable.