write_ecm_specs12
Purpose:
-
Create the asam3_specs files.
Enter:
-
write_ecm_specs12 <testid> <reg_name> <hostIP> <port> <localIP> <config_cal_file_path>
Where:
-
testid
Specify the testid associated with the tri specs that define the test conditions.
reg_name
Specify the registered name of the instance of asam3cli.
hostIP
Specify the IP address used within the cuty specs file.
port
Specify the port used within the cuty specs file.
localIP
Specify the local IP address to receive the data stream.
config_cal_file_path
Specify the path for the configuration and calibration files. The path must have a single quote around it
Example:
-
write_ecm_specs12 my_tpid asam3_1 10.0.0.1 57005 10.2.2.2 ‘C:\TestRequest’