cal_x_units
Purpose:
-
Identify the units of the x-variable in the calibration table. This allows the @cal_table ( value, table_name ) to properly perform the conversion. Any table that is used in any expression with @cal_table() must have the x-units in the table.
Run the ‘bld_tables’ process’ to make the table active.
Enter:
-
cal_x_units < table_name > < units >
Where:
-
table_name
Specify the calibration table name.
units
Specify units of the x-variable.
Example:
-
cal_x_units int_mnf_p psi
The above example identifies psi units in the int_mnf table.
Notes:
-
The actual calibration table filename will have the .tbl extender and will be found in the /cell/tables/ directory. The ‘table_name’ argument does not include the .tbl extender.