ai_specs
Purpose:
-
Process analog input specifications.
Enter:
-
ai_specs [input_specification_file]
Where:
-
input_specification_file
Optional. Specify the input specification filename. The default is /specs/inpt_specs.nnn.
Example:
-
ai_specs
The above command processes the file inpt_specs.nnn for analog input channels at test cell nnn.
Notes:
-
The ai_specs command processes the specified input specification file for the analog input channels that are specified within it. The default input specification file is named inpt_specs.nnn, where nnn represents the three digit test cell n.
To successfully configure analog input channels, the calibration tables associated with each input channel must be defined and active prior to issuing the ai_specs command. This is accomplished by issuing the command “bld_tables”.