to

Purpose:

Set Torque target

Enter:

to <target> [ramp_rate]

Where:

target

Specify the target value for the torque controller. Note: This may be the Throttle controller or the Dyno controller depending on which controller is controlling torque.

Units may be entered that may be different than the feedback variable.  If not entered, units are assumed to be those of the feedback.
Enter the target value without the “units” designation. The program assumes units of the torque target variable.

ramp_rate

Optional. Specify the rate the torque target should be changed to from its current value to the new target value.

Units may be entered that may be different than the feedback variable.  If not entered, units are assumed to be those of the feedback.
Enter the ramp rate value with the “units” designation.  The program assumes units of the torque target variable (units/sec).

Example:

to 1500
The above command sets the torque target for the controller to 1500 in units of the torque feedback variable

to 1200[N-m] 100
The above command sets the torque target for the controller to 1200 N-m. The target will be ramped from its current value to the new target value at the rate of 100 [units]/sec, where [units] are the units of the torque feedback.

Notes:

This command resets the “unattended_test” flag to indicate that the cell is being run manually.

See Also:

th, th_ramp, dy,dy_ramp, sp, Cyflex Engine Controls